

Katalogauszüge

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and
Katalog auf Seite 1 öffnen
Introduction VA-LCP Forefoot/Midfoot Plates 2.4/2.7 2 Controlled Compression Technique 6 Screw Insertion Techniques 9 Surgical Technique Preparation 10 Product Information Screws 27 Synthes Biomaterials Overview 36 A Image intensifier control This description alone does not provide sufficient background for direct use of the product. Instruction by a surgeon experienced in handling this product is highly recommended Reprocessing, Care and Maintenance of Synthes Instruments For general guidelines, function control and dismantling of multi-part instruments, please contact your local sales...
Katalog auf Seite 3 öffnen
Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and Compression feature Compression holes used with compres- sion wires and forceps allow for tactile Variable angle Screw holes allow up to 1 5° off-axis screw angulation in all directions. Minimized soft tissue irritation Low profile plates with rounded edges and highly polished surface minimize soft tissue irritation. The system consists of general and pro- cedure-specific plates, variable angle locking and cortex screws, and a com- pression feature, to aid in reconstructive foot...
Katalog auf Seite 4 öffnen
Variable Angle (VA) Locking Plates Straight Fusion Plate 2.4/2.7, L-Fusion Plate 2.4/2.7, VA locking T-Fusion Plate 2.4/2.7, VA locking Cloverleaf Fusion Plate 2.4/2.7, (refer to Technique Guide 036.001.234) (refer to Technique Guide 036.001.238) Opening Wedge Plates (refer to Technique Guide 036.001.236)
Katalog auf Seite 5 öffnen
AO Principles In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1, 2 The principles as applied to the Variable Angle LCP Forefoot / Midfoot System 2.4 / 2.7 are as follows: Anatomic reduction The use of variable angle locking technology allows fragment specific fixation by providing the flexibility to lock screws in trajectories that can diverge from the central axis of the plate hole. Variable screw angles provide fixation options for a variety of fracture patterns. Stable fixation Variable angle locking screws create a locked...
Katalog auf Seite 6 öffnen
Indications The Straight Fusion Plates, T-Fusion Plates, L-Fusion Plates, Cloverleaf Fusion Plates and X-Plates of the Variable Angle LCP Forefoot / Midfoot System 2.4 / 2.7 are indicated for fractures, deformations, revisions and replantations of bones (e.g. tarsals, metatarsals and phalanges) and bone fragments, particularly in osteopenic bone. Synthes 5
Katalog auf Seite 7 öffnen
Controlled Compression Technique The plates included in the Variable Angle LCP Forefoot / Midfoot System 2.4 / 2.7 aid in reconstructive foot surgery by allowing controlled compression with the use of compression wires and compression forceps. Compression feature – Allows for up to 4 mm of compression – Tactile compression – Designed within the plate to minimize additional soft tissue dissection – Allows for final screw fixation after compression is achieved Compression wires – 1.6 mm diameter, 150 mm overall length – Seven thread lengths: 10, 15, 20, 25, 30, 35 and 40 mm – Stop feature...
Katalog auf Seite 8 öffnen
1 Position plate Place the plate on the bone, ensuring that the plate is placed appropriately according to the specific procedure. 2 Insert compression wires Instrument 03.211.410.01– Compression Wire л 1.6 mm, 03.211.440.01 length 150 mm, thread length 10 – 40 mm Estimate the appropriate thread length needed for the plate and bone combination. Bicortical fixation is recommended. Using a wire driver, insert the compression wire through the compression wire hole and through both bone cortices. Important: To minimize stripping of the bone threads, slow the insertion once the spherical stop of...
Katalog auf Seite 9 öffnen
Controlled Compression Technique Compress using forceps with Compression Wire Move the ratcheting switch so the forceps ratchet when clos- ng preventing the spring from opening the forceps. Place the compression forceps in position, ensuring that the arms are around the compression wire spheres. Compress by squeezing the handles. Important: Compression is tactile, but be careful not to over compress. This may cause the compression wires to strip out When the ratcheting mechanism is in the correct position, compression can be maintained without holding the forceps. O This leaves the hands...
Katalog auf Seite 10 öffnen
Screw Insertion Techniques The plate holes of the Variable Angle LCP Technology 2.4 / 2.7 accept 2.4 mm and 2.7 mm Variable Angle (VA) Locking Screws. Screws can be inserted using two different techniques: – Variable angle technique – Pre-defined nominal angle technique Variable angle technique To drill variable angle holes at a +/-15° deviation from the nominal trajectory of the locking hole, insert the tip of the conical VA-LCP drill sleeve (03.211.003 / 03.110.023) and key into the cloverleaf design of the VA-LCP hole. VA-LCP drill sleeve, conical, for Drill Bits (03.211.003/03.110.023)...
Katalog auf Seite 11 öffnen
01.211 .X01 VA-/Cortex Screws 2.4, in Modular Tray, Vario Case System 01.211 .X02 VA-/Cortex Screws 2.7, in Modular Tray, Vario Case System 01.211 .X03 General Fusion Plates VA 2.4/2.7, in Modular Tray, Vario Case System 01.211.103 Instruments VA 2.4/2.7, in Modular Tray, Vario Case System Modular Tray, Vario Case System Select the plate according to the arthrodesis, osteotomy or fracture pattern and the anatomy of the patient. Note: This technique guide describes the application of VA locking plates for various indications in the forefoot and mid- foot of the "Variable Angle LCP...
Katalog auf Seite 12 öffnen
Prepare joint surface Remove the cartilage and prepare the joint surface for an arthrodesis. The surface of the joint can be manipulated to achieve the desired correction. Open osteotomy Create an osteotomy starting from the medial side. Do not cut through the bone leaving the lateral cortex intact. Reduce fracture O Reduce the fracture under the image intensifier and if neces- sary, fix with Kirschner wires or reduction forceps. The reduc- tion method will be fracture-specific.
Katalog auf Seite 13 öffnenAlle Kataloge und technischen Broschüren von Depuy Synthes
-
2.0 mm LCP® Distal Ulna Plate
20 Seiten
-
VA LCP ® Distal Radius System
8 Seiten
-
Building on Success
16 Seiten
-
RADIUS OF CURVATURE
3 Seiten
-
Introducing The Variable Angle
12 Seiten
-
HEALIX Anchor™ 3.4 mm
2 Seiten
-
Small Battery Drive II
4 Seiten
-
HEALIX ADVANCE
4 Seiten
-
3.5 mm LCP™ Medial
15 Seiten
-
Titanium Sternal Fixation System
34 Seiten
-
MatrixRIB®FixationSystem
86 Seiten
-
External Midface Distractor System
43 Seiten
Archivierte Kataloge
-
TRAVIOS Operationstechnik
20 Seiten
-
2.4 mm VA LCP™
4 Seiten
-
Mandible Trauma Solutions
2 Seiten
-
Power line II
4 Seiten
-
Concorde
28 Seiten
-
LCP Intercarpal
31 Seiten
-
LCS® COMPLETE™
2 Seiten
-
Cementing Total Knee Replacements
12 Seiten
-
CORAIL® Hip System Design Rationale
12 Seiten
-
Synthes TPLO.
8 Seiten
-
SynFix-LR System
56 Seiten
-
ATB Anterior Tension Band Plate
32 Seiten
-
CONDUIT™
15 Seiten
-
Brochure_FINAL
2 Seiten
-
DePuy Synthes
81 Seiten
-
Anspach
3 Seiten
-
Orthopedic Foot Instruments
32 Seiten
-
PINNACLE® Hip Solutions
12 Seiten
-
Corail
24 Seiten
-
GLOBAL Advantage Surgical Technique
32 Seiten
-
S-ROM® NOILES™
68 Seiten
-
TRI-LOCK® Product Rationale
12 Seiten
-
Reclaim Surgical Technique
44 Seiten
-
Speed
2 Seiten
-
attune
80 Seiten
-
HAMMERLOCK® 2
2 Seiten
-
DePuy Glenoid Solutions
2 Seiten
-
Trauma Solutions. Elbow
4 Seiten
-
Polar
4 Seiten
-
Alveolar Distractor.
4 Seiten
-
Piezoelectric System
4 Seiten
-
Air Power Line II
6 Seiten
-
LCP Clavicle Hook Plate
4 Seiten
-
TruMatch Pin Guides
16 Seiten
-
P F N A
8 Seiten
-
SKILL, DEDICATION,
16 Seiten
-
Orthopaedics. Overview
20 Seiten
-
DURALOC
16 Seiten
-
Marathon Cemented Cup
20 Seiten
-
REEF Surgical Technique
16 Seiten
-
MatrixNEURO
8 Seiten
-
Anspach XMax
4 Seiten
-
Anspach eMax 2 Plus
4 Seiten
-
Small Electric Drive
4 Seiten
-
Air Pen Drive
4 Seiten
-
Colibri II
4 Seiten
-
Spine
25 Seiten
-
MultiLoc Humeral Nailing System.
4 Seiten
-
Expert Hindfoot Arthrodesis Nail
48 Seiten
-
LCP Distal Fibula Plates
32 Seiten
-
LCP Distal Tibia Plate - Low Bend
24 Seiten
-
TomoFix
60 Seiten
-
Expert Tibial Nail PROtect
16 Seiten
-
Expert Tibia Nail
84 Seiten
-
Sacral Bars
16 Seiten
-
Pelvic C-Clamp
20 Seiten
-
Low Profile Pelvic System
16 Seiten
-
Proximal Femoral (Hook) Plate
24 Seiten
-
LCP
24 Seiten
-
PFNA
112 Seiten
-
HCS 1.5, 2.4, 3.0
36 Seiten
-
LCP Wrist Fusion
32 Seiten
-
LCP Compact Hand
28 Seiten
-
VA-LCP Elbow
48 Seiten
-
Distal Radius
44 Seiten
-
Olecranon
30 Seiten
-
LCP Hook Plate
28 Seiten
-
DHP & Olecranon
4 Seiten
-
LCP S-A
4 Seiten
-
Epoca
4 Seiten
-
Philos
32 Seiten
-
MultiLoc
68 Seiten